Weed control can help with fall armyworm management
Glyphosate-resistant plants serve as a green bridge for the insect in the off-season
The production process in agriculture consists of several phases, from the construction and maintenance of the area where the crop will be harvested, through the selection of nutrient sources, the development of the soil profile structure, to the selection of varieties to be planted, with the aim of obtaining maximum productivity. In this context, the use of fertilizers is essential to provide a sufficient amount of nutrients for the entire crop cycle, both in applications during the planting process, and also throughout its development, with cover applications, requiring technologies that allow greater operational performance and excellent uniformity across the entire application range.
The correct management of fertilizers leads to increased efficiency and productivity in a treated area, if the four Cs of good practices for the efficient use of fertilizers are used at the same time: the right source, in the right dose, at the right time and in the right place (Reetz, 2017). The right source refers to the combination of fertilizers according to the needs of the crop and the condition of the soil in which it will be grown, according to the agronomic recommendations obtained with the help of analyzes and mapping of that soil. The right dose corresponds to the application of the necessary amount of fertilizer for the crop to establish itself and provide the expected productivity. Doses smaller than necessary will harm its growth, and at the same time, excessive doses will result in waste and economic and environmental damage. The right time corresponds to the definition of when to carry out applications, considering that the demand for macro and micronutrients is different according to each phenological stage of the crop. And the right place is to make nutrients available uniformly throughout the applied area, taking into account the mobility of nutrients in the soil for crops to absorb them efficiently. In summary, good practices in fertilizer management must be adopted to ensure that nutrients react with the soil and plants, in order to allow greater root absorption and reduce losses.
The use of solid inorganic fertilizers is very common in the field, and their application on the surface is carried out in most production areas. Fertilizers based on nitrogen, phosphorus and potassium (N, P and K) are macronutrients, and require higher application doses, and may include the addition of some sources of micronutrients in different formulations. Due to some factors such as ease of operation and higher operational yield, which are targets of rural producers in general, one of the most common ways of applying fertilizers and correctives is broadcast fertilization. Another important factor is the collaboration of this technique to meet the objectives of the direct planting system, which is to maintain the straw layer on the soil surface and help preserve water and nutrients.
The fertilizer application technology adopted is one of the factors that directly influence the guarantee of the appropriate dose and location for deposition of these nutrient sources. Centrifugal fertilizer and fertilizer distribution equipment is widely used due to its operational capacity and possibilities for adjusting doses and application ranges (Baio et al., 2012; Laghari et al. 2014).
Centrifugal distribution systems use horizontal rotating discs made up of fins or blades, which, through centrifugal force, launch fertilizers into the soil at varying distances, depending on their characteristics, such as particle size, grain shape and density. The solutions adopted in the distribution equipment have a significant impact on the quality of distribution of these inputs, such as the care taken when placing fertilizers on the discs, in addition to the geometry of the blades and discs. Another fundamental factor for the quality of the application is the physical quality of the fertilizer, which can be verified by the particle size pattern and its ability to maintain the grain shape (absence of dust). When applying formulas with different grains, for example, the lighter grains with lower density and size will be thrown at shorter distances, and the heavier grains will be thrown at greater distances, determining different application ranges and causing their segregation in the area. applied. This can generate problems with crop productivity, as it impacts the management of fertilizers in the soil (Ortiz-Cañavate, 2003; Miserque et al..
For the application process to be carried out with quality and efficiency, it is also necessary to calibrate the equipment according to the fertilizer used, the required dose and the desired application range. This operation of calibrating the application range is considered difficult and requires a lot of time from the equipment operator, and this contributes to poor calibration of the distributors, and is often not carried out in the field. As in all agricultural operations, there is a great demand for more agile solutions that make distributor calibration easier and safer.
To carry out a careful analysis of the performance of broadcast fertilizer distribution, a standardized assessment is necessary that uses collection in trays aligned transversally to the equipment's path, throughout the entire desired application range. The values obtained from collecting and weighing the fertilizer deposited in the trays are used to calculate the transversal coefficient of variation (CV). Due to the different broadcast application system solutions available on the market, it is possible to find equipment that cannot guarantee uniformity across the entire application range, and also leave failures or not reach the desired range. Problems arising from poor fertilizer application, with CV values above 20%, not guaranteeing the application range configured on the equipment in the soil, can cause serious economic losses. Some studies show that a CV of approximately 40% can bring reductions of up to 20% in harvest productivity (Mersmann et al., 2013; and Yule & Grafton, 2013).
Various equipment and distribution system solutions are offered on the agricultural market and some of them aim to guarantee the quality of fertilizer dosage and distribution with ease and safety in calibrating application ranges. With the aim of evaluating the quality of distribution with some formulations commonly applied in the field, including fertilizers and correctives, Fundação Mato Grosso carried out tests with different application ranges and dosages, of the Uniport 5030 NPK and Tellus 10.000 NPK fertilizer application systems, from company Máquinas Agrícolas Jacto S.A.
The evaluations of ammonium monophosphate (MAP), simple superphosphate (SFS) and potassium chloride (KCl) fertilizers, and limestone correction, were carried out in the municipality of Rondonópolis (MT). For each fertilizer/corrector, different application range widths and product doses were tested.
For the procedure for adjusting the desired range in this equipment, the drop point settings on the disc obtained by Jacto's SmartSet system were used for each fertilizer and each application range width. After obtaining this information, the rapid distribution quality verification method proposed by Jacto for its distributors was carried out. The method consists of, after adjusting the drop point on the disc, performing an overlapping application (round trip) and collecting a sample of the applied content with just four trays allocated along half the desired strip width. The contents of the trays are collected in test tubes to check uniformity between them. If there is a difference in volumes between the beakers, it is possible to fine-tune the drop point on the disc by reporting the values indicated in the beakers on the equipment display.
After this, a standardized check of the distribution quality of the application was carried out with three repetitions for each adjustment between product, width and dose. Each repetition consisted of three passes in the same direction to accumulate product in the collection trays and increase differences at the time of weighing. The researchers sought to carry out applications with wind speeds below 8km/h. The application speed of the products was 18km/h. Before applying the products, flow calibrations were carried out to achieve the desired doses. 147 trays measuring 0,5m x 0,5m x 0,07m were allocated, with an internal structure with a regular pattern of 0,05m x 0,05m to prevent product ricochets. Four trays were removed from the machine tracks, two on each side. After each application, the contents of all trays were collected and their mass was measured for subsequent data analysis. The calculation of coefficients of variation (CVs) was carried out using the Adulanço software, which measures the application CV depending on the work mode (alternating or continuous) for different widths and provides the values in percentages. The CV values considered were those calculated for the desired working width in the work protocol. After calculating the CVs, the data were subjected to analysis of variance using the F test and in the case of a significant effect, the Tukey test was performed to compare means at 10% probability.
The results are presented for each fertilizer/corrector, considering CV reference values as: ideal 10%.
For SFS fertilizer, strip widths of 28m, 32m and 36m were tested at doses of 250kg/ha and 500kg/ha. CV values for SFS were the best among all products. On average, the CV is within the acceptable range for the applied variation sources. Added to this, surprisingly low values were found at a width of 28m and a dose of 250kg/ha, in addition to allowing applications at acceptable levels above 36m. These results demonstrate the potential of the distribution system to provide the maximum possible uniformity, given that Brazilian standards border on CVs of 30% or more for this fertilizer.
For MAP fertilizer, strip widths of 28m, 32m and 36m were tested for the 250kg/ha dose, and 28m and 32m for the 150kg/ha dose. The CV values for MAP were influenced by the application dose, however still within acceptable ranges for good distributions, similar to SFS. These results are significant in comparison to Brazilian standards, as it is possible to find CV values closer to 20% for MAP, even after several adjustment adjustments.
For limestone correction, a width of 12m and doses of 1.500kg/ha and 2.500kg/ha were used. The change in the applied dose changed the uniformity of application. In addition to the greater quantity of product to be applied, the wind may have influenced the quality of distribution. Increasing the dose increased the CV, however the values remained within the acceptable range, mainly considering that the limestone was dry, and also the influence of the wind.
For the KCl fertilizer, strip widths of 28m, 32m, 36m and 42m and doses of 150kg/ha and 250kg/ha were tested. Even under adverse conditions of the product used in the tests, with the presence of dust and small grains, CV values were achieved within acceptable limits for widths of 32m and 36m. In the 28m application, some adjustments to the drop point on the disc and/or changing the set of blades were necessary to improve quality (the equipment has a set of blades ideal for smaller ranges). Uniformity across the 42m application width was hampered by inferior product quality, and achieved CVs outside the acceptable range.
In general, for the fertilizers, doses and application ranges tested, the Uniport 5030 NPK fertilizer machine presented excellent performance in terms of ease of calibration and the quality of application of broadcast fertilizers and correctives, reaching large operational ranges with superior quality in relation to to the average of Brazilian standards. To work with the machine with better application uniformities, you should look for fertilizers with good physical qualities. However, the distribution system proved to be efficient in achieving large application widths (compatible with the sprayer bar widths) with acceptable quality, even with different particle sizes of the fertilizers tested.
The application range adjustment system proposed by Jacto's distribution technology is sensitive to changes in the drop point, a situation that is linked to its precision, allowing CVs within an ideal level when well adjusted. In the tests carried out, applications with acceptable uniformities were noted, with special emphasis on the application of SFS, with excellent uniformity results. When applying limestone, it was influenced by the wind and the application uniformities were acceptable.
As demonstrated in the tests, the equipment requires adjustments to demonstrate its best operational quality. The time required to carry out a “fine adjustment” of the range adjustment with three repetitions was less than 15 minutes and using less than 500kg of inputs to achieve the appropriate adjustment, i.e., reduction of fertilizer waste and savings for the farmer .
Gustavo Barbosa Micheli, Daniel Petreli da Silva, Máquinas Agrícolas Jacto S.A.; Marcus Vinícius Corradi Leal, Mato Grosso Foundation
Receive the latest agriculture news by email